GE Aespire S5 Anesthesia Machine with 7900 Smartvent

450,000.00

Product description

The GE Aespire S5 serves as an advanced anesthesia machine that integrates the precise ventilation capabilities of the 7900 SmartVent system. The GE Aespire S5 measures 134.5 centimeters (H) x 72 centimeters (W) x 73 centimeters (D) with a total weight of 108 kilograms. The machine accepts different gas types and provides a sturdy work area while optional bag attachments and power outlets enhance its usefulness throughout diverse clinical requirements. The machine functions optimally in demanding conditions between 10°C and 40°C and handles high levels of humidity successfully.

Description

SPECIFICATIONS

Physical Weight & Dimensions

  • Height: 134.5 cm/52.9 in
  • Width: 72 cm/28.3 in
  • Depth: 73 cm/28.7 in
  • Weight: Approximately 108 kg/238 lb

Top Shelf

  • Weight limit: 34 kg/75 lb
  • Width: 66 cm/26 in
  • Depth: 40 cm/15.75 in

Work Surface

  • Height: 81.7 cm/32.2 in
  • Size: 2160 cm-2/334 in-2

DIN Rail

Side of machine: 34.5 cm/13.6 in

Drawers (internal dimensions)

  • Height: 17.5 cm/6.9 in
  • Width: 33 cm/13 in
  • Depth: 26.5 cm/10.4 in

Absorber Bag Arm (optional)

  • Arm length: 30.5 cm/12 in
  • Bag arm height (adjustable): 87 cm (34.3 i) to 104 cm (40.9 in)

Casters

  • Diameter: 12.5 cm/5 in
  • Brakes: Individual locking front casters

Electrical Specifications

Current Leakage

  • 100/120 V: < 300μA
  • Power
  • Power input: 100-120 Vac, 50/60 Hz
  • Power cord: Length: 5 m/16.4 ft
  • Rating: 15A @ 120 Vac

Inlet/outlet modules (120 V)

  • System circuit breakers: 15A
  • Outlets (optional): 4 outlets on back, 3-2A, 1-3A individual breakers, optional isolation transformer

Pneumatic Specifications

Auxiliary Common Gas Outlet

Connector: ISO 22 mm OD and 15 mm ID

Gas Supply

  • Pipeline input range: 240 kPa to 600 kPa/35 psig to 88 psig
  • Pipeline connections: DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359). All fittings available for O2, N2O, and Air, and contain pipeline filter and check valve.
  • Cylinder input: Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve
    Note: Maximum 3 cylinders; two inboard mounted, one outboard mounted.
  • Primary regulator diaphragm minimum burst pressure: 2758 kPa/400 psig
  • Primary regulator nominal output: < 338 kPa/49 psig Pin indexed cylinder connections
  • < 407 kPa/59 psig DIN cylinder connections

Environmental Specifications

System Operation

  • Temperature: 10° to 40°C/50° to 104°F
  • Humidity: 15 to 95% relative humidity (non-condensing) per IEC 68-2-3
  • Altitude: -440 to 3565 m/500 to 800 mmHg

System Storage

  • Temperature: -15° to 50°C/-5° to 122°F
  • Humidity: 10 to 95% relative humidity (including condensing) per IEC 68-2-3
  • Altitude: -440 to 3565 m/500 to 800 mmHg
  • Oxygen cell storage: -15° to 50°C/5° to 122°F; 10 to 95% relative humidity; 500 to 800 mmHg

Electromagnetic Compatibility

  • Immunity: Complies with all requirements of EN 60601-1-2
  • Emissions: CISPR 11 group 1 class B
  • Approvals: UL 2601-1; CSA C22.2 #601.1; EN/IEC 60601-1; CE 0197

Reviews

There are no reviews yet.

Be the first to review “GE Aespire S5 Anesthesia Machine with 7900 Smartvent”

Your email address will not be published. Required fields are marked *